X-DR Static BT & WS
Solid solutions for practices, radiological centres and small clinics.
Technical data
Bucky table with floor mounted tube stand
Table height
692 mm (27.2“)
692 mm (27.2“)
Tabletop dimension
Standard: 2260 x 755 mm (89“ x 30“)
Optional: 2000 x 755 mm (79“ x 30“)
Standard: 2260 x 755 mm (89“ x 30“)
Optional: 2000 x 755 mm (79“ x 30“)
Tabletop mobility
Longitudinal movement: ± 470 mm (18.5“);
optional ± 340 mm at 2000 mm (13.4“ at 79“)
Transverse movement: ± 150 mm (6“)
Longitudinal movement: ± 470 mm (18.5“);
optional ± 340 mm at 2000 mm (13.4“ at 79“)
Transverse movement: ± 150 mm (6“)
Bucky drawer travel range
560 mm (22“)
560 mm (22“)
Object - film/detector - distance
67 mm (2.6“)
67 mm (2.6“)
Al equivalent value
@ 100 kV: 0.9 mm (0.04“) Al; optional 0.7 mm (0.03“) Al
@ 100 kV: 0.9 mm (0.04“) Al; optional 0.7 mm (0.03“) Al
Patient bearing load
max.: 230 kg (507 lbs); optional 250 kg (551 lbs)
max.: 230 kg (507 lbs); optional 250 kg (551 lbs)
Focal spot vertical travel - horizontal X-ray beam
250 - 1892 mm (9.8“ - 74.5“)
250 - 1892 mm (9.8“ - 74.5“)
Focal spot vertical - film distance
max. 1267 mm (49.9“)
max. 1267 mm (49.9“)
Focal spot vertical - tabletop distance
max. 1200 mm (47.2“)
max. 1200 mm (47.2“)
Angulation X-ray tube assembly
Around horizontal support arm: ± 180°
Around tube column (optional): ± 90°
Detents at: - 90°, 0°, + 90°
Around horizontal support arm: ± 180°
Around tube column (optional): ± 90°
Detents at: - 90°, 0°, + 90°
Vertical travel supporting arm
1642 mm (64.6“)
1642 mm (64.6“)
Tube stand longitudinal travel
1285 mm (50.6“)
1285 mm (50.6“)
Bucky wall stand
Vertical movement of the acquisition unit
370 - 1680 mm (14.6“ x 66.1“)
370 - 1680 mm (14.6“ x 66.1“)
Columm height
2133 mm (84“)
2133 mm (84“)
More technical data
Generator
CMP 200 DR, 50 kW, max. 630 mA, max. 150 kV, max. 200 kHz, AEC, hand switch, 3 phases/N/PE, 400 V, incl. consol
CMP 200 DR, 50 kW, max. 630 mA, max. 150 kV, max. 200 kHz, AEC, hand switch, 3 phases/N/PE, 400 V, incl. consol
Tube
Toshiba E7252X, focal spots 0.6 / 1.2 mm, 300 kHu, max. 150 kV, incl. high voltage cable, weight approx. 18 kg (39.7 lbs)
Toshiba E7252X, focal spots 0.6 / 1.2 mm, 300 kHu, max. 150 kV, incl. high voltage cable, weight approx. 18 kg (39.7 lbs)
Collimator
Manually turnable, LED Lamp, integrated timer, laser alignment
Manually turnable, LED Lamp, integrated timer, laser alignment
DAP
Dose area product measurement device, integrated display, automatic integration into X-AQS X-ray journal
Dose area product measurement device, integrated display, automatic integration into X-AQS X-ray journal
Measuring chamber AEC
3-field carbon measuring chamber with cable
3-field carbon measuring chamber with cable
Optional
Tube: RAD-14, RAD-21
Other tubes and generators on request
Tube: RAD-14, RAD-21
Other tubes and generators on request
Warranty
12-month warranty